Dry Substation (VPI)
Durable. Reliable. Engineered for Excellence.
MGM Transformers’ Dry Substation (VPI) transformers are built to meet the demands of modern applications where performance, longevity, and environmental safety are non- negotiable. Designed with precision and manufactured using cutting-edge technology, our VPI transformers offer a seamless blend of innovation and reliability.
Key Features:
- Voltage ratings: 600 V to 34.5kV
- Power Ratings: 500kVA to 10,000kVA
- Custom high voltage/low voltage switchgear interface designs
- Non-standard substation solutions for unique challenges
- Low partial discharge levels for extended life
- White label options available

STANDARD FEATURES
- DOE 2016 Efficiency Compliant
- UL/CUL/CE/CSA listings
- Aluminum or Copper Windings
- 50/60/400 Hz
- 220 °C Insulation
- Vacuum Pressure Impegnated
- 150°, 115° or 80 °C Temperature Rise
- IEEE C57.12.01
- Seismically Certified per ASCE/SEI 7-05
- OSHPD OSP Pre Approval
GENERAL CONSTRUCTION
Coils are Vacuum Pressure Impregnated (VPI) with solventless polyester resin, ensuring complete impregnation of the windings and insulation. The finished VPI coils are incredibly strong, readily dissipate heat and are protected against moisture, dirt, and most industrial contaminants. Winding designs vary based on voltage, BIL and application. For all units the insulation system will be 220 °C
ENCLOSURE
The standard enclosure is NEMA 1, Category C construction. Enclosures are suitable for lifting, jacking, rolling or skidding with provisions for lifting from the transformer base. High voltage and low voltage ANSI ground pads are provided.
The enclosure paint finish is neat, clean and highly resistant to corrosion. Metal surfaces are thoroughly cleaned of scale, oil, grease, rust and other foreign matter before painting. Unless specified otherwise, paint color shall be ANSI 61 (light gray). NEMA 3R outdoor enclosures available.
CORE
The transformer cores are constructed of non-aging, high grade, grain oriented silicon steel laminations with high magnetic permeability. Magnetic flux densities are kept well below the saturation point. Core laminations are free of burrs and stacked without gaps. Mitered construction cores standard for low loss and high efficiency. The core clamping brackets are designed to provide even distribution of clamping forces to the core yokes and legs.
FORCED AIR COOLING
All units rated 750 kVA and higher can have added thermostatically controlled fans to increase the output capacity of the unit and give a forced air-cooled rating of 33% above the self-cooled rating. Control wiring (wire markers included), a thermal sensor and a fan controller will be supplied.
AUDIBLE SOUND LEVELS
The transformer shall be designed to meet IEEE sound levels for dry-type transformers. As an option, transformers designed at -3dB below IEEE C57.12.01 standard sound levels are available.
PRODUCT COORDINATION
When specified, transformers can be close-coupled to a multitude of High Voltage and Low Voltage Switchgear.
TESTING
Each transformer shall receive the following standard production tests in accordance with IEEE C57.12.91
- Resistance test
- Polarity & phase relation test
- Turns ratio test
- No-load loss & exiting current test
- Impedance and load-loss test
- Applied potential test
- Induced potential test
- Additional optional tests available upon request
SPECIAL APPLICATIONS
- Low loss designs
- Rectifier transformer designs
- Special ambient temperature designs
- High overload capacity designs
- Special/low sound level designs
- 50 Hz designs
- Series/parallel windings
- Retrofit to specific dimensions
- K-factor ratings
- Special Paint
- Auto transformers
- Liquid filled transformer replacement
Product Literature
INSTRUCTION SHEETS & MANUALS
Contact Us
Bull Rush
Emergencies happen and we’re here to respond. We will work 24/7 till the emergency transformer is done or your money back!