In Stock 600V Class Dry Type General Purpose Distribution Transformers Skip to content
low-voltage-dry
prodcut-high

LOW VOLTAGE TRANSFORMER - STOCKED

MGM general purpose low voltage transformers are stocked in 20 major cities across the continental United. They are rated for 600V for supplying power loads from electrical distribution systems. Standard features for stocked units include:
  • DOE 2016 Efficiency Compliant
  • UL 506, UL 1561 Listed
  • Aluminum or Copper Windings
  • 60 Hz
  • Min. 60 dB Common Mode Noise Attenuation (Single shield)
  • 150°C Temperature Rise
  • Seismically Certified per ASCE/SEI 7-05
  • OSHPD OSP Pre Approval

Numquam Eius Modi

Non proident, sunt in culpa qui officia deserunt mollit

Duis aute irure dolor >

With our two state of the art manufacturing facilities we can offer quick turnaround time with free shipping through out the continental United States. Ask about our Bull Rush program for expediting your order.

480D – 208Y/120 | 60 HZ, 150ºC, 3 PHASE, ALUMINUM​

CAT #
ALT #
RATING
H (in)
W (in)
D (in)
WEIGHT (lbs)
DIMS DWG
HT15A3B2-D16
15YS*D16
15 KVA
28
21
14
235
A
HT30A3B2-D16
30YS*D16
30 KVA
32
26.5
17
355
B
HT45A3B2-D16
45YS*D16
45 KVA
32
26.5
17
425
B
HT75A3B2-D16
75YS*D16
75 KVA
38.5
28.5
20
595
B+
HT112A3B2-D16
112YS*D16
112.5 KVA
40.5
31.5
21.75
795
C
HT150A3B2-D16
150YS*D16
150 KVA
40.5
36.5
21.75
1,020
C+
HT225A3B2-D16
225YS*D16
225 KVA
51.5
40.5
26.5
1,580
D
HT300A3B2-D16
300YS*D16
300 KVA
51.5
40.5
26.5
1,875
D
HT500A3B2-D16
500YS*D16
500 KVA
66
50.5
32
3,295
E
HT750A3B2-D16
750YS*D16
750 KVA
80.25
64
50
3,850
F

480D – 240d/120ct | 60 HZ, 150ºC, 3 PHASE, ALUMINUM

CAT #
ALT #
RATING
H (in)
W (in)
D (in)
WEIGHT (lbs)
DIMS DWG
HT15A3K2-D16
15DS*D16
15 KVA
28
21
14
240
A
HT30A3K2-D16
30DS*D16
30 KVA
32
26.5
17
355
B
HT45A3K2-D16
45DS*D16
45 KVA
32
26.5
17
425
B
HT75A3K2-D16
75DS*D16
75 KVA
38.5
28.5
20
590
B+
HT112A3K2-D16
112DS*D16
112.5 KVA
40.5
31.5
21.75
790
C
HT150A3K2-D16
150DS*D16
150 KVA
40.5
36.5
21.75
1,015
C+
HT225A3K2-D16
225DS*D16
225 KVA
51.5
40.5
26.5
1,570
D
HT300A3K2-D16
300DS*D16
300 KVA
51.5
40.5
26.5
1,865
D
HT500A3K2-D16
500DS*D16
500 KVA
66
50.5
32
3,215
E

240D – 208Y/120 | 60 Hz, 150ºC, 3 PHASE, ALUMINUM

CAT #
ALT #
RATING
H (in)
W (in)
D (in)
WEIGHT (lbs)
DIMS DWG
HT15C3B2-D16
15CS*D16
15 KVA
28
21
14
235
A
HT30C3B2-D16
30CS*D16
30 KVA
32
26.5
17
355
B
HT45C3B2-D16
45CS*D16
45 KVA
32
26.5
17
425
B
HT75C3B2-D16
75CS*D16
75 KVA
38.5
28.5
20
595
B+
HT112C3B2-D16
112CS*D16
112.5 KVA
40.5
31.5
21.75
795
C
HT150C3B2-D16
150CS*D16
150 KVA
40.5
36.5
21.75
1,010
C+

240DX480 – 120Y/240 | 60 Hz, 150ºC, 1 PHASE, ALUMINUM

CAT #
ALT #
RATING
H (in)
W (in)
D (in)
WEIGHT (lbs)
DIMS DWG
HS10C3B2-D16
10SS*D16
10 KVA
28
21
14
175
A
HS15C3B2-D16
15SS*D16
15 KVA
28
21
14
205
A
HS25C3B2-D16
25SS*D16
25 KVA
32
26.5
17
270
B
HS37C3B2-D16
37SS*D16
37.5 KVA
32
26.5
17
345
B
HS50C3B2-D16
50SS*D16
50 KVA
32
26.5
17
385
B
HS75C3B2-D16
75SS*D16
75 KVA
38.5
28.5
20
530
B+
HS100C3B2-D16
100SS*D16
100KVA
40.5
31.5
21.75
620
C

480D – 208Y/120 | 60 HZ, 150ºC, 3 PHASE, COPPER

CAT #
ALT #
RATING
H (in)
W (in)
D (in)
WEIGHT (lbs)
DIMS DWG
HT15A3B1-D16
15YSC*D16
15 KVA
28
21
14
231
A
HT30A3B1-D16
30YSC*D16
30 KVA
32
26.5
17
340
B
HT45A3B1-D16
45YSC*D16
45 KVA
32
26.5
17
418
B
HT75A3B1-D16
75YSC*D16
75 KVA
38.5
28.5
20
599
B+
HT112A3B1-D16
112YSC*D16
112.5 KVA
40.5
31.5
21.75
806
C
HT150A3B1-D16
150YSC*D16
150 KVA
40.5
36.5
21.75
942
C+
HT225A3B1-D16
225YSC*D16
225 KVA
51.5
40.5
26.5
1,755
D
HT300A3B1-D16
300YSC*D16
300 KVA
51.5
40.5
26.5
2,068
D
HT500A3B1-D16
500YSC*D16
500 KVA
66
50.5
32
3,382
E

480D – 240D/120CT | 60 Hz, 150ºC, 3 PHASE, COPPER

CAT #
ALT #
RATING
H (in)
W (in)
D (in)
WEIGHT (lbs)
DIMS DWG
HT15A3K1-D16
15DSC*D16
15 KVA
28
21
14
227
A
HT30A3K1-D16
30DSC*D16
30 KVA
32
26.5
17
340
B
HT45A3K1-D16
45DSC*D16
45 KVA
32
26.5
17
422
B
HT75A3K1-D16
75DSC*D16
75 KVA
38.5
28.5
20
590
B+
HT112A3K1-D16
112DSC*D16
112.5 KVA
40.5
31.5
21.75
798
C
HT150A3K1-D16
150DSC*D16
150 KVA
40.5
36.5
21.75
938
C+
HT225A3K1-D16
225DSC*D16
225 KVA
51.5
40.5
26.5
1,743
D
HT300A3K1-D16
300DSC*D16
300 KVA
51.5
40.5
26.5
2,040
D
HT500A3K1-D16
500DSC*D16
500 KVA
66
50.5
32
3,175
E

FEATURES

STANDARD FEATURES
  • DOE 2016 Efficiency Compliant
  • UL 506, UL 1561 Listed
  • Aluminum or Copper Windings
  • 60 Hz
  • Electrostatic Shield
  • Min. 60 dB Common Mode Noise Attenuation (Single shield)
  • 150°C Temperature Rise
  • ANSI C57.12.01
  • Seismically Certified per ASCE/SEI 7-05
  • OSHPD OSP Pre Approval
SOUND LEVELS
MGM 600 Volt class general purpose dry type transformers are designed to meet NEMA ST-20 sound levels.
ACCESSORIES
  • Seismic Kits
  • Wall Brackets
  • Rodent Screens
  • Weathershield Kits
TESTING AND QUALITY ASSURANCE

As part of our quality assurance process, all 600 Volt MGM Transformers go through a rigorous ANSI/IEEE test plan to ensure optimum performance. These tests include:

  • Winding resistance test
  • Turn ratio test
  • Polarity and phase relation test
  • No load losses and exciting current test
  • Impedance and load loss test
  • Applied potential test
ENCLOSURES
MGM ventilated transformers utilize a NEMA 2 rated drip proof metal enclosure with natural draft ventilation. MGM dual rated enclosures are suitable for indoor or outdoor applications and are standard on all models except the 225, 300, and 500 kVA transformers (optionalWeather-shield Kits are available for these units).
VOLTAGE TAPS

Taps will compensate for the high or low line voltages. MGM 600 Volt class transformers are provided with 6 primary taps:

  • 2@ 2-1/2% FCAN
  • 4@ 2-1/2% FCBN

Benefits

BULL RUSH PROGRAM
Need it fast? We can deliver. Emergencies happen and we can expedite the manufacturing of your units to meet your delivery requirements. Ask about our Bull Rush program when you place your order and we can manufacture and ship your unit in as fast as 2 working days!
MADE IN USA

MGM Transformer Company can manufacture your units at our 120,000 square foot plant in the U.S. and source the raw materials solely from American companies if required. By doing so we can certify your units to be compliant with any of the various “Buy U.S.” statutes (either state or federal). Please make sure to specify your requirements at the time of order.

Sign up for MGM Updates