Products

General Purpose
- DOE 2016 Efficiency Compliant
- UL 506, UL 1561 Listed
- Aluminum or Copper Windings
- 60 Hz
- Electrostatic Shield
- Min. 60 dB Common Mode Noise Attenuation (Single shield)
- 150°C Temperature Rise
- ANSI C57.12.01
- Seismically Certified per ASCE/SEI 7-05
- OSHPD OSP Pre Approval
Numquam Eius Modi
Non proident, sunt in culpa qui officia deserunt mollit
Duis aute irure dolor >
Model
The Liebert MC features an aluminum microchannel coil with a variable speed fan for each coil section. Constructed with an aluminum cabinet, the Liebert MC is a low-profile,
direct-drive, propeller fan-type unit suitable for mounting outdoors. It provides for the heat rejection of either one or two separate refrigeration circuits, matching heat rejection
capacity varying with the outdoor ambient temperatures and with each corresponding compressor’s heat rejection requirements. The unit is quiet and corrosion resistant. Copper
pipe connections are provided for brazing of copper field piping. Connections are located next to the electrical panel. All electrical connections and controls are enclosed in an
integral weatherproof section of the condenser.
Liebert MC Microchannel Outdoor Condenser, 28 – 220kW | |
---|---|
Weight | 339-1835 lbs |
Weight | 339-1835 lbs |
Height | 63 in |
Height | 63 in |
Height | 63 in |
FEATURES
STANDARD FEATURES
- DOE 2016 Efficiency Compliant
- UL 506, UL 1561 Listed
- Aluminum or Copper Windings
- 60 Hz
- Electrostatic Shield
- Min. 60 dB Common Mode Noise Attenuation (Single shield)
- 150°C Temperature Rise
- ANSI C57.12.01
- Seismically Certified per ASCE/SEI 7-05
- OSHPD OSP Pre Approval
SOUND LEVELS
ACCESSORIES
- Seismic Kits
- Wall Brackets
- Rodent Screens
- Weathershield Kits
TESTING AND QUALITY ASSURANCE
As part of our quality assurance process, all K Factor Rated MGM Transformers go through a rigorous ANSI/IEEE test plan to ensure optimum performance. These tests include:
- Winding resistance test
- Turn ratio test
- Polarity and phase relation test
- No load losses and exciting current test
- Impedance and load loss test
- Applied potential test
ENCLOSURES
VOLTAGE TAPS
Taps will compensate for the high or low line voltages. K Factor Rated transformers are provided with 6 primary taps:
- 2@ 2-1/2% FCAN
- 4@ 2-1/2% FCBN
Benefits
NATIONWIDE STOCK
BULL RUSH PROGRAM
MADE IN USA
MGM Transformer Company can manufacture your units at our 120,000 square foot plant in the U.S. and source the raw materials solely from American companies if required. By doing so we can certify your units to be compliant with any of the various “Buy U.S.” statutes (either state or federal). Please make sure to specify your requirements at the time of order.