For hard-to-reach indoor installation locations, MGM offers Triplex Indoor VPI Transformers. These can help reduce or eliminate unnecessary site tear down and reconstruction  by fitting a standard-sized unit into tight-spaces. 

To accomplish this, MGM uses single-phase VPI transformer modules in a banked assembly. They can be customized to suit your application requirements and provide the same proven methods as our standard three-phase transformers. 

All units are factory pre-assembled and tested to guarantee proper fit and performance, before they are disassembled for shipment. Our enclosures can also be knocked down to further facilitate movement and allow them to fit through tighter spaces and areas with limited entry points.

FEATURES

STANDARD FEATURES
  • DOE 2016 Efficiency Compliant
  • UL 506, UL 1561 Listed
  • Aluminum or Copper Windings
  • 60 Hz
  • Electrostatic Shield
  • Min. 60 dB Common Mode Noise Attenuation (Single shield)
  • 150°C Temperature Rise
  • ANSI C57.12.01
  • Seismically Certified per ASCE/SEI 7-05
  • OSHPD OSP Pre Approval
SOUND LEVELS
K Factor Rated dry type transformers are designed to meet NEMA ST-20 sound levels.
ACCESSORIES
  • Seismic Kits
  • Wall Brackets
  • Rodent Screens
  • Weathershield Kits
TESTING AND QUALITY ASSURANCE

As part of our quality assurance process, all K Factor Rated MGM Transformers go through a rigorous ANSI/IEEE test plan to ensure optimum performance. These tests include:

  • Winding resistance test
  • Turn ratio test
  • Polarity and phase relation test
  • No load losses and exciting current test
  • Impedance and load loss test
  • Applied potential test
ENCLOSURES
MGM ventilated transformers utilize a NEMA 2 rated drip proof metal enclosure with natural draft ventilation. MGM dual rated enclosures are suitable for indoor or outdoor applications and are standard on all models except the 225, 300, and 500 kVA transformers (optionalWeather-shield Kits are available for these units).
VOLTAGE TAPS

Taps will compensate for the high or low line voltages. K Factor Rated transformers are provided with 6 primary taps:

  • 2@ 2-1/2% FCAN
  • 4@ 2-1/2% FCBN

Benefits

BULL RUSH PROGRAM
Need it fast? We can deliver. Emergencies happen and we can expedite the manufacturing of your units to meet your delivery requirements. Ask about our Bull Rush program when you place your order and we can manufacture and ship your unit in as fast as 2 working days!
MADE IN USA

MGM Transformer Company can manufacture your units at our 120,000 square foot plant in the U.S. and source the raw materials solely from American companies if required. By doing so we can certify your units to be compliant with any of the various “Buy U.S.” statutes (either state or federal). Please make sure to specify your requirements at the time of order.

Sign up for MGM Updates